%20Kopyas%C4%B1%20(10).png)

Test Merkezimiz
01
Test Merkezimiz
Kaplan Trafo has prioritized quality and reliability with its independent test laboratories since 2005. We perform the tests of both our own production and external products with state-of-the-art equipment and our expert engineering staff. We apply routine, type and special tests in accordance with national and international standards, and act with the principles of accuracy, impartiality and confidentiality. We minimize risks by continuously improving our quality management system and improve our processes with customer feedback. As Kaplan Trafo, we set quality standards in the sector by providing the most reliable test results.
Conversion Ratio Measurement and Connection Group Control
01
Transformatörün sargıları arasındaki gerilim oranının doğruluğunu belirleyerek bağlantıların ve sargıların durumunu analiz ederiz.
Insulation Resistance Measurement
02
Sargıların toprağa ve birbirine karşı yalıtım durumunu kontrol ederek işletme güvenliği için referans değerler elde ederiz.
Winding Resistance Measurement
03
Sargı ve terminal bağlantılarının kontrol edilmesini sağlar, yük kayıplarının hesaplanmasına yönelik referans oluştururuz.
Measurement of No-load Currents and Losses
04
Transformatörün işletmedeki performansını ve enerji verimliliğini değerlendirmek için boştaki akım ve kayıpları ölçeriz.
Kısa Devre Kayıpları ve Gerilim Ölçümü
05
We analyze the short circuit losses and voltage that determine the operating performance of the transformer.
İndüklenen Test
06
We test the safety of the transformer by checking the insulation strength between phases, splines and windings.
Uygulanan Gerilim Dayanım Testi
07
We perform high voltage tests to verify the transformer's insulation resistance against overvoltages.
Yağ Delinme Testi
08
We ensure safe working conditions by measuring the insulation level of transformer oil.
Partial Discharge Test
09
We perform analyses to prevent premature failures by detecting micro-level electrical discharges that may occur in the transformer insulation system.
Impulse Voltage Test
10
We determine whether the transformer is safe against high voltage surges by measuring its resistance against sudden voltage fluctuations.
Oil Analysis Tests
11
By examining the chemical and physical properties of transformer oil, we evaluate the insulation quality and the overall health of the transformer.
Heat Distribution Analysis with Thermal Camera
12
By detecting temperature differences that occur during operation, we identify possible overheating problems in advance.
Sound and Vibration Measurements
13
We analyze whether the transformer complies with the standards by measuring the noise and vibration levels created by the transformer during operation.
Humidity and Water Content Analysis
14
We perform checks to increase insulation life and performance by measuring the moisture level in transformer oil.
Frequency Response Analysis
15
By evaluating the mechanical integrity of transformer windings, we help detect potential damage in advance.